Image Description
Construction Mandatory Standard
Mandatory

Asphalt and Bitumen Boiler

This mandatory standard should be applied at all construction projects: Mandatory Fire Precautions for asphalt / bitumen boiler

  • Compliance with CASSE Clause 15.8 - Fire Precautions
  • Armoured LPG supply hoses
  • Must be situated on a non-combustible, insulating base
  • LPG cylinder minimum 3m away from boiler
  • Auto thermostat controls fitted to boiler
  • Close fitting specific lid to boiler
  • Never left unattended whilst in operation
  • Keep additional fuel cylinders to a minimum and store at least 6m away from the boiler
  • Hot Works Permit controlled at all times
  • Fire extinguishers must include, 2 No. dry powder, 1 foam extingisher

Pat Boyle